What should pay attention to when using low voltage circuit breaker

What should pay attention to when using low voltage circuit breaker The basic installation method of the circuit breaker is vertical installation. However, tests have shown that, when the thermal-action long-delay release is installed horizontally, although the heat dissipation conditions are somewhat different, its operation value does not change much. As an electromagnet for short-circuit protection, although the reaction has some relationship with gravity, the horizontal load is The error is only about 5% to 10%. Therefore, a molded case circuit breaker using a thermal-electromagnetic release can also be mounted horizontally or horizontally. However, if the tripping device is fully electromagnetic type (oil cup trip unit), the error value of the action value when mounted horizontally is as high as 20%-30%. In view of this, the molded case circuit breaker of the oil-filled cup trip unit can only be installed vertically. The universal type (frame type) circuit breaker can only be mounted vertically. This is related to the direction of its handle operation, and it is related to the energy storage operation of the spring, and the electromagnet release, closing device, under voltage release, etc. are related to the gravity compared with the plastic case. In addition, many types of universal circuit breakers have drawer-type installations, and they cannot be operated horizontally or horizontally. In this regard, all universal circuit breakers are required to be installed vertically, and the required tilt angle with the vertical plane is not greater than 5.

If the line voltage is reduced to 70% of the rated voltage (known as the breakdown voltage), the motor will not start, the lighting fixtures will be dull, the resistance furnace will be insufficiently heated, and the operating motor will be reduced to about 50% when it is operating ( Known as the critical voltage), stalling (dragging the motor and stopping the motor) occurs. The current of the motor is suddenly increased to 6 IN. The time is slightly longer and the motor will be burned. In order to avoid the above-mentioned situation, it is required to install an undervoltage release on the circuit breaker. The operating voltage of the undervoltage release is set at (70% - 35%) rated voltage. Undervoltage release has instantaneous and delay type (with 1s, 3s, 5s...-.). Delay-type undervoltage release is used on main lines or important branches, and instantaneous type is often used on general branches. For areas with poor power supply quality, the voltage itself fluctuates greatly and approaches the upper voltage limit of the undervoltage release. This situation is not suitable for undervoltage releases.

If the conductive connection (soft connection), tripping and moving, static contact, arc extinguishing chamber, arc exit, etc. are not in a plane, such as DZ5-20, TL-100C, TL-225B and DWl5-1600, 2500, 4000 And DW45 and other types of circuit breakers, they can be on the line (circuit breaker's "ON'' end of the power cord, "OFF" under the termination of the load), but also under the line ("ON" on the termination of the load, "OFF" The lower end is connected to the power supply. However, most molded case circuit breakers (such as HSMl, DZ20, TO, TG, H series, etc.) can only enter the line and cannot enter the line. DWl 5-630 is also only able to enter the line. The reason is: When the short-circuit current is disconnected, there is no transient restoration voltage on the moving contact of the upper line, and the breaking conditions are good.When the lower wiring is connected, the front of the moving contact bar (when the upper line enters the line is the back) has soft connection and double Metals, heating elements, etc., have a recovery voltage on the movable contact, the breaking conditions are severe, and the arcing time is long, which may lead to a short-circuit between the phases.Because the moving contacts are mostly linked by a common axis, they are closely connected. Soft couplings and trips, if they are disconnected due to short-circuiting to generate ionized gas or conduct electricity If the insulation is lowered due to dust, short-circuits between phases can be easily caused.In case of circuit breakers that can only enter the line, if it is necessary to enter the line due to installation conditions, the short-circuit breaking capacity must be reduced, generally 20% to 30%, and the short-circuit current is expected. Big drop, small drop.

To connect to a LAN, a Network Cable is essential. The common network cables in the LAN are mainly twisted pair, Coaxial Cable, and optical cable. Twisted pair is a data transmission line composed of many pairs of wires. It is characterized by its low price, so it is widely used, such as our common telephone line. It is used to connect to the RJ45 crystal head. It has two kinds of STP and UTP, and we usually use UTP.


Chinese name
cable
Foreign name
Reticle
 
Application range
The internet

Network Cable

Network Cable,Usb Networking Cable,Dish Network Cable,Network Chin Cable

Jiangsu QiSheng Cable Co., Ltd. , https://www.shuaihe-cable.com

Posted on